ACU400V4K
• Thanks to the long-standing system of competence EGTRONICS ensures other ranges of I/O voltage range.
Input voltage range (500~700V), Output voltage range (275~425V)
Global No.1 Innovator EGTRONICS
• Unidirectional operation
• Very high efficiency (above 96%)
• Non-Isolated type. It allows to be very compact and light
• ZVS(Zero Voltage Switching) topology ensures very low switching losses and excellent EMC -behavior
• CAN interface
POWER |
UNIT |
ACU400V4K |
REMARK |
Power ratings |
[ kW ] |
4 |
|
Input side voltage range (Nominal) |
[ V ] |
500 ~ 750 (600) |
Can be adjusted |
Input side current ratings (Nominal) |
[ A ] |
6 ~ 8.9 (7.4) |
|
Output side Voltage range |
[ V ] |
275 ~ 425 (400) |
|
Output side current ratings |
[ A ] |
10 |
|
Control Power |
[ V ] |
16 ~ 32 (24) |
|
Structure(Type) |
[ - ] |
Uni-Directional |
|
Efficiency @ 80% Load |
[%] |
Over 98 |
|
Efficiency @ Max Load |
[%] |
Over 97 |
|
OPERATING CONDITION |
UNIT |
ACU400V4K |
REMARK |
Location |
[ - ] |
in Case |
|
Environ. Temp.(operating) |
[ ℃ ] |
-40 ~ 85 |
|
Environ. Temp(storage) |
[ ℃ ] |
-40 ~ 105 |
|
MECHANICAL |
UNIT |
ACU400V4K |
REMARK |
Weight |
[ kg ] |
4.7 |
|
Size(W*D*H) (mm*mm*mm) |
[ - ] |
|
|
Vibration class(G) |
[ g ] |
6 |
|
Protection Class |
[ - ] |
IP69K |
|
COOLING |
UNIT |
ACU400V4K |
REMARK |
cooling method |
[ - ] |
Water cooling |
|
Required water flow rate |
[ℓ/min.] |
5 (Max 15) |
|
Pressure |
[bar] |
1 (Max 2) |
|
coolant Temp. |
[ ℃ ] |
50 (30~65) |
|