DLDC
• One is 360Vdc for chilling devices and the other one is for 24Vdc devices.
• This model has been supplied to Hyundai Motors since 2016.
Global No.1 Innovator EGTRONICS
• Unidirectional operation
• Very high efficiency (above 96%)
• Galvanically Isolated type
• ZVS(Zero Voltage Switching) topology ensures very low switching losses and excellent EMC - behavior
• Step Down (Buck converter) Type
• CAN interface
POWER |
UNIT |
LDC |
HDC |
REMARK |
Power ratings |
[ kW ] |
5.8 |
12 |
|
Input side voltage range (Nominal) |
[ V ] |
534 ~ 828 (720) |
534 ~ 828 (720) |
Can be adjusted |
Input side current ratings (Nominal) |
[ A ] |
7.8 ~ 15.4 (9) |
16.2 ~ 25(18.5) |
|
Output side Voltage range (Nominal) |
[ V ] |
16 ~ 30 (28) |
300 ~ 370 (360) |
|
Output side current ratings |
[ A ] |
207 |
33 |
|
Control Power (Nominal) |
[ V ] |
8 ~ 32 (24) |
8 ~ 32 (24) |
|
Structure(Type) |
[ - ] |
Uni-Directional |
Uni-Directional |
|
Efficiency |
[%] |
Over 92 |
Over 97 |
|
OPERATING CONDITION |
UNIT |
DLDC |
REMARK |
Location |
[ - ] |
in Case |
|
Environ. Temp.(operating) |
[ ℃ ] |
-40 ~ 85 |
|
Environ. Temp(storage) |
[ ℃ ] |
-40 ~ 105 |
|
MECHANICAL |
UNIT |
DLDC |
REMARK |
Weight |
[ kg ] |
33 |
|
Size(W*D*H) (mm*mm*mm) |
[ - ] |
485 * 470 * 139 |
|
Vibration class(G) |
[ g ] |
6 |
|
Protection Class |
[ - ] |
IP69K |
|
COOLING |
UNIT |
DLDC |
REMARK |
cooling method |
[ - ] |
Water cooling |
|
Required water flow rate |
[ℓ/min.] |
10 ~ 20 LPM |
|
Pressure |
[bar] |
2 |
|
coolant Temp. |
[ ℃ ] |
65 |
|